Chapter 7
Using WCDMA/HSPA+ Signal Analyzer
196
JD700B Series User’s Guide
CDP Table
The CDP Table is used to look at a numeric and textual description of all the active code channels in the
signal.
Setting measure setup
After configuring test parameters as described in the “Configuring test parameters” on page 173, you can
continue your measurement. The measurement settings can be saved and recalled as a file. You can also
use JDViewer, PC application software to configure a measure setup, save as a file, and load the file on to
the instrument.
Procedure
1
Press the
MEASURE SETUP
hot key.
2
Optional
. To set the scramble code, complete the following steps:
Toggle the
Scramble
soft key between
Auto
and
Manual
.
Enter a value by using the numeric keys to set manually.
Press the
Enter
soft key.
3
Optional
. Press the
Detect Mode
soft key, and then select the signal standard option:
WCDMA
,
HSDPA
, or
HSPA+
. HSDPA is set by default.
4
To set the S-CCPCH information of the system to be tested, complete the following steps:
Press the
S-CCPCH
soft key.
Toggle the
S-CCPCH
soft key between
On
and
Off
to enable or disable the S-CCPCH.
Press the
Spread Factor
soft key, and then select the spread factor option:
4
,
8
,
16
,
32
,
64
,
128
, or
256
.
Press the
Spread Code
soft key to set the spread code.
Enter a value by using the numeric keys.
Press the
Enter
soft key.
5
To set the PICH information of the system to be tested, complete the following steps:
Press the
PICH
soft key.
Toggle the
PICH
soft key between
On
and
Off
to enable or disable the PICH.
Press the
Spread Factor
soft key, and then select the spread factor option:
4
,
8
,
16
,
32
,
64
,
128
, or
256
.
Press the
Spread Code
soft key to set the spread code.
Enter a value by using the numeric keys.
Press the
Enter
soft key.
6
Optional
. To set the threshold, complete the following steps:
Press the
Threshold
soft key.
Enter a value by using the numeric keys.
Press the
Enter
soft key.