Chapter 11
Using EV-DO Signal Analyzer
JD700B Series User’s Guide
397
Figure 235 SEM measurement with EV-DO signal analyzer
NOTE
You can use the
LIMIT
hot key to analyze your measurements with the user-definable
limit and Pass/Fail indication. See “Setting limit for RF tests” on page 401 for more
information.
ACPR
The Adjacent Channel Power Ratio (ACPR) is defined as the ratio of the average power in the adjacent
frequency channel (or offset) to the average power in the transmitted frequency channel. It may be
expressed as the ratio of the integrated signal power in the adjacent channel to the integrated signal power
in the main channel.
After configuring test parameters as described in the “Configuring test parameters” on page 389, your
measurement result is displayed on the screen as like the following example, Figure 236.
Figure 236 ACPR measurement with EV-DO signal analyzer