7URXEOHVKRRWLQJ&KDUW
Assuming that all other system components, including the Smart Repeater
unit and APS6 module are working properly and that proper system power
has been supplied to the luminaire:
Symptom
Probable Cause
Corrective
Action
No luminaire cali-
bration
Loose input cable connection
Blown LCB 5A or 1/16A fuse
Fulty LCBLoose PTM belt
Faulty PTM
Faulty lamp input cable
Luminaire will not
come on-line
Loose LCB connection
Faulty LCB
Faulty lamp input cable
Lamp will not start
No intensity
Bad lamp
Faulty lamp socket/wires
Faulty lamp input cable
Faulty ignitor board
No tilt response
Loose tilt cable connection
Faulty tilt cable
Faulty tilt mechanism
Faulty LCB
No pan response
Loose pan cable connection
Faulty pan cable
Faulty pan mechanism
Faulty LCB
Jerky or dragging
tilt movement
Loose belt
Loose or broken tilt pulley
Jerky or dragging
pan movement
Loose belt
Loose or broken pan pulley
No color control
Bad stabilizer
Missing stabilizer washer
Faulty sensor (out of calibration)
Faulty LCB
Faulty color wheel motor