![background image](http://html1.mh-extra.com/html/vari-lite/vl6-series/vl6-series_service-manual_3517718108.webp)
110
9
$5,
/
,7(
9/9/%6
327
/
80,1$,5(
6
(59,&(
0
$18$/
0 2 . 9 6 3 8 . 0 0 1 0
C O N F I D E N T I A L
2 3 - A u g - 9 9
Step 12. Install new pulley/collet assembly on pan tube.
a. Slide installation tool onto pan tube opposite flat side as
shown in (
). Ensure that tab is oriented upwards.
Figure 3-29: Pan Driven Pulley Removal and Replacement
b. Matching “D” notch of pulley with pan tube flat side, slide
pulley down onto pan tube until it rests against installation
tool. Collet should be on side of pulley opposite tool
(
CAUTION: Do not overtighten pulley acorn nuts or pulley may crack.
c. Using 5/16 inch open end wrench, fully tighten, but do not
overtighten, 6-32 acorn nuts in a cross pattern to secure collet
and pulley to pan tube.
Figure 3-30: Installation Tool Placement
PANTOOL
Pan Stop Ring
Collet
Pan Pulley
Pan Tube
“D” Notch
Flat Side
Installation Tool
(Orient tab upwards.)
Pan Tube
Cross Member
Collet
Pulley
6-32 Acorn Nut
Installation Tool
Stabilizer