6HULHV9/&RPP6\VWHP'LDJUDP
Note: This is only one example of a system setup using a VL6 luminaire.
Many others are possible. Refer to System Installation and Checkout
manual (02.3004.0200) for more information.
The typical Series 300 system contains AC line disconnects, Mini ACS
Racks, Modular Racks with C3 and APS6 power supply modules, a mini-
Artisan2 control console, Repeater Boxes, Smart Repeater units, Smart
Repeater Plus units, and VL5, VL6, and VL7 luminaires, and VLM
moving mirrors. Series 300 data, 24Vdc, and lamp power are provided by
repeater units to Series 300 luminaires via lamp cables. Dimming power
for VL5/VL5B luminaires is provided by C3 power supply modules, which
require the use of an SPC-36 SixPack controller. Arc power for VL5Arc/
VL6/VL7 luminaires is provided by APS6 power supply modules. The
SPC-36 controller is optional for controlling APS6 modules.
mini-Artisan2 Console
Mini ACS Rack
AC Line Disconnect
Mod Rack w/ SPC-36 Controller
Smart Repeater Unit
Smart Repeater
Plus Unit
VL5B
VL6
VL5
VL7
S300 Lamp Cables
To
House
Service
Console Snake Cable
Mac
Computer Rack
S200
Cable
Lamp
S200
Cable
Lamp
VL7
VL7
APS
Trunk
Cable
2/0 Pigtails
8/5 Hubbell Cable
S200
Cable
Lamp
300DGRM
Mod
Rack
S200
Cable
Lamp
(5-Wire)
SPC36