6SDFLQJ5HTXLUHPHQWV
To avoid collisions during pan and tilt movement, luminaires must be
installed at a minimum distance from each other.
Table 1-1: Luminaire-To-Luminaire Distance Requirement
Example
Find minimum distance between a VL5 luminaire & a VL6 luminaire:
Step 1. On chart above, locate VL6 luminaire on top row and locate VL5
luminaire on side row.
Step 2. From VL6 block on top row, follow chart down. From VL5 block
on side row, follow chart to right.
Step 3. Where two rows meet, locate the correct minimum distance
(17.25 in. or 438 mm).
LUMINAIRE
TYPE
VL2B/
VL2C
VL4
VL5/
VL5B/
VLArc
VL6
VL7
VLM
VL2B/
VL2C
21.50 in
546 mm
19.50 in
495 mm
19.75 in
502 mm
19.00 in
483 mm
23.75 in
603 mm
19.50 in
495 mm
VL4
19.50 in
495 mm
17.50 in
445 mm
17.75 in
451 mm
17.00 in
432 mm
21.75 in
552 mm
17.50 in
445 mm
VL5/VL5B/
VL5Arc
19.75 in
502 mm
17.75 in
451 mm
18.00 in
457 mm
17.25 in
438 mm
22.00 in
559 mm
17.75 in
451 mm
VL6
19.00 in
483 mm
17.00 in
432 mm
17.25 in
438 mm
16.50 in
419 mm
21.25
540 mm
17.00 in
432 mm
VL7
23.75 in
603 mm
21.75 in
552 mm
22.00 in
559 mm
21.25
540 mm
26.00
660 mm
21.75 in
552 mm
VLM
19.50 in
495 mm
17.50 in
445 mm
17.75 in
451 mm
17.00 in
432 mm
21.75 in
552 mm
17.50 in
445 mm