9/7HVW&RGHVDQG3DUDPHWHUV
Following is a list of the test codes that can be applied from the Smart
Repeater Plus unit to test the luminaire, as well as error codes and test
parameter information. These apply only to the VL5 family of luminaires.
CAUTION: Tests should not be run for more than 30 seconds, as this can
further damage the luminaire. Any tests run at FULL SPEED should not
be run for more than 15 seconds.
Table 3-1: VL5 Luminaire Family Mechanical Tests
Table 3-2: VL5 Luminaire Family Default Tests
Test Number
Test Parameter
Error Codes/Comments
000
Start
9
End Stop (OPEN)
103 No Reset (PAN)
001
Pan
8
End Stop (CLOSED)
203
No Reset (PAN)
002
Tilt
7
Speed 1 (25%)
104
No Reset (PAN)
004
Diffuser
6
Speed 2 (35%)
204
No Reset (PAN)
005
Intensity
(VL5Arc Only)
5
Speed 3 (45%)
4
Speed 4 (55%)
006
Blue Filter
3
Speed 5 (65%)
204
No Change (Tilt)
007
Amber Filter
2
Speed 6 (75%)
008
Magenta Filter
1
Speed 7 (85%)
0
Speed 8 (FULL SPEED)
012
All Motors (synchronized)
013
All Motors (unsynchronized)
912
End Motor (in cal. position)
Test Number
Test
Functions
31
Pan and Tilt
701
Pan 25% Speed
702
Tilt 25% Speed
37
VL5 Functions
704
Edge 25% Speed
706
Blue Filters 25% Speed
707
Amber Filters 25% Speed
708
Magenta Filters 25% Speed