116
9
$5,
/
,7(
9/9/%6
327
/
80,1$,5(
6
(59,&(
0
$18$/
0 2 . 9 6 3 8 . 0 0 1 0
C O N F I D E N T I A L
2 3 - A u g - 9 9
/&%$)XVH5HSODFHPHQW
Parts:
1 EA ASSY, 1/16A, DATA FUSE (23.9634.0168)
Tools:
Pliers, needle-nosed (as needed)
To remove and replace LCB 1/16A fuse:
Step 1. Remove power to luminaire.
Step 2. At board-side yoke leg, remove yoke leg cover.
CAUTION: Always use anti-static precautions when working with PCBs.
Step 3. Remove 4-pin comm MTA connector from header at P9.
Step 4. At 1/16A fuse mini-board, carefully pull up and out, Data Fuse
Assembly (contains four fuses). Needle-nosed pliers may be
necessary to pull out of fuse block.
Figure 3-34: LCB 1/16A Fuse Removal and Replacement
Step 5. Replace fuse by doing Steps 2 through 4 in reverse.
Fuse Assembly
(Four 1/16A Fuses)