,QSXW&DEOH5HSODFHPHQW
Parts:
as needed:
1 EA CABLE ASSY, VL5 INPUT W/ GRN-YEL (25.9634.0180)
Tools:
Screwdriver, #2 PhillipsNutdriver, 5/16 inch
Screwdriver, #1 slottedChannel locks
To remove and replace input cable:
Step 1. Remove power to luminaire.
Step 2. Remove both yoke leg covers.
Step 3. At yoke top cross member, remove four 6-32x5/16" PPZ screws
and #6 internal tooth lock washers that secure heatshield to cross
member and remove heatshield (
).
Figure 3-36: Disconnecting Input Cable Wiring
Step 4. Disconnect input cable wiring.
a. At terminal strip, using #1 slotted screwdriver, disconnect
lamp wires extending from head.
b. At ground stud, using 5/16 inch nutdriver, remove two 6-32
Keps nuts securing ring terminals of ground wires. Remove
ring terminal of input ground cable from stud.
Step 5. Push all input cable wiring through yoke leg cutouts.
6-32x5/16”PPZ
Screw
#6 Int. Tooth
Lock Washer
Heatshield
Disconnect
Lamp Power
Bundles
Disconnect
Input Data
& Power
Cables
VL5Arc Version
Not Shown