70
9
$5,
/
,7(
9/9/%6
327
/
80,1$,5(
6
(59,&(
0
$18$/
0 2 . 9 6 3 8 . 0 0 1 0
C O N F I D E N T I A L
2 3 - A u g - 9 9
/DPS:LOO1RW6WDUW1R,QWHQVLW\
Assuming the following:
•
APS6 module (modular rack) is properly configured (with jumper),
connected, working, and has not tripped a circuit breaker.
•
Smart Repeater unit is properly connected (neon light should be lit).
If the luminaire lamp will not start or has no intensity:
Step 1. Replace lamp. Refer to
.
Step 2. If new lamp will not start, replace lamp socket.
Step 3. If symptom still persists, check continuity of input cable:
a. Remove tilt-side yoke leg cover.
b. Using meter, check continuity of lamp power pins of input
cable connector to terminal strip located in yoke leg.
c. Replace pins as needed. Refer to
.
d. If problem still persists, replace input cable. Refer to
Cable Replacement” on page 118
Meter from cable end
to terminal strip.