/DPS5HSODFHPHQW
Parts:
1 EA LAMP,VL6,400WATT SHORT ARC (71.2528.0400)
Tools:
none
To replace the lamp:
Step 1. Remove power from luminaire (and APS6 module).
CAUTION: Turn only the 1/4-28 captive screw (slotted). The other three
screws are focus adjustment controls and turning these will alter the
luminaire beam.
Step 2. At rear of luminaire head, at lamp assembly, unscrew 1/4-28
captive screw that secures lamp assembly to luminaire head and
carefully pull lamp assembly out of luminaire head (
).
Figure 3-15: Lamp Replacement
Step 3. At lamp socket, firmly grip ceramic base of lamp and carefully
pull from socket.
Step 4. Install replacement lamp in socket by firmly pushing lamp into
socket.
Step 5. Re-install lamp assembly by aligning guide pins with rear
assembly and sliding fully into luminaire head.
Step 6. Secure lamp assembly to luminaire head by securing 1/4-28
captive screw.
Lamp Assembly
Guide Pin
Lamp Socket
Lamp