Appendix E - Communication Protocols-Modus MM147 - D4 Hot Melt Unit
158
Parameter List - Continued
Short Name
(Melton)
Modbus Hex
Address
(NC Spec)
Write/Read
Description
Comments
TC2
0x0178
W/R Sunday
Type ON 2
Not Used by Valco CPU
HD2
0x0179
W/R Sunday
Hour OFF 2
Not Used by Valco CPU
MD2
0x017A
W/R Sunday
Minute OFF 2
Not Used by Valco CPU
TD2
0x017B
W/R Sunday
Type OFF 2
Not Used by Valco CPU
DIA
0x017C
W/R
Day
Sunday = 0 -> Saturday = 6
HORA 0x017D W/R
Hour
0-23
MINUTOS 0x017E W/R
Minute
0-59
RELOJ 0x0180 W/R
Clock – weekly connection
and disconnection hours
Not Used by Valco CPU
BAJO MANT
0x0181
W/R
Setback
0 = Normal, 1 = Setback
P10
0x0182
W/R
Time until filter change
P9
0x0183
R
Total Hours Unit On Time
Dep actual
0x0184
R
Tank Temperature
All Temperatures in ºC w/ 25 ºC offset added
M1 actual
0x0185
R
Hose 1 Temperature
All Temperatures in ºC w/ 25 ºC offset added
P1 actual
0x0186
R
Gun 1 Temperature
All Temperatures in ºC w/ 25 ºC offset added
M2 actual
0x0187
R
Hose 2 Temperature
All Temperatures in ºC w/ 25 ºC offset added
P2 actual
0x0188
R
Gun 2 Temperature
All Temperatures in ºC w/ 25 ºC offset added
M3 actual
0x0189
R
Hose 3 Temperature
All Temperatures in ºC w/ 25 ºC offset added
P3 actual
0x018A
R
Gun 3 Temperature
All Temperatures in ºC w/ 25 ºC offset added
M4 actual
0x018B
R
Hose 4 Temperature
All Temperatures in ºC w/ 25 ºC offset added
P4 actual
0x018C
R
Gun 4 Temperature
All Temperatures in ºC w/ 25 ºC offset added
M5 actual
0x018D
R
Hose 5 Temperature
All Temperatures in ºC w/ 25 ºC offset added
P5 actual
0x018E
R
Gun 5 Temperature
All Temperatures in ºC w/ 25 ºC offset added
M6 actual
0x018F
R
Hose 6 Temperature
All Temperatures in ºC w/ 25 ºC offset added
P6 actual
0x0190
R
Gun 6 Temperature
All Temperatures in ºC w/ 25 ºC offset added
ESTADO
EQUIPO
0x0191
R
Status Word
Not Used by Valco
0x0192
W/R
Tank 2 Temperature Setpoint
All Temperatures in ºC
0x0193
W/R
Aux 1 Temperature Setpoint
All Temperatures in ºC
0x0194
W/R
Aux 2 Temperature Setpoint
All Temperatures in ºC
0x0195
W/R
Hose 7 Temperature Setpoint
All Temperatures in ºC
0x0196
W/R
Gun 7 Temperature Setpoint
All Temperatures in ºC
0x0197
W/R
Hose 8 Temperature Setpoint
All Temperatures in ºC
0x0198
W/R
Gun 8 Temperature Setpoint
All Temperatures in ºC
0x0199
W/R
Spare
Not Used by Valco CPU
Summary of Contents for D4
Page 1: ...D4 Hot Melt Unit Manual Number MM147 Revision Date 6 2018 ...
Page 4: ......
Page 10: ...Table of Contents MM147 D4 Hot Melt Unit 10 Module Status LED 170 Link Activity LED 170 ...
Page 20: ...Section 2 Safety and Use MM147 D4 Hot Melt Unit 20 ...
Page 22: ...Section 3 Basic Features MM147 D4 Hot Melt Unit 22 ...
Page 35: ...MM147 D4 Hot Melt Unit Section 5 Setup 35 Section 5 Setup Control Panel ...
Page 42: ...Section 5 Setup MM147 D4 Hot Melt Unit 42 Set Language Continued Next Page ...
Page 43: ...MM147 D4 Hot Melt Unit Section 5 Setup 43 Set Language Continued ...
Page 44: ...Section 5 Setup MM147 D4 Hot Melt Unit 44 Set Temperature Units ...
Page 47: ...MM147 D4 Hot Melt Unit Section 5 Setup 47 Hose Valve Temperature Continued ...
Page 54: ...Section 5 Setup MM147 D4 Hot Melt Unit 54 Beacon Alarm Setup Continued ...
Page 55: ...MM147 D4 Hot Melt Unit Section 5 Setup 55 Beacon 2 ...
Page 70: ...Section 5 Setup MM147 D4 Hot Melt Unit 70 Sequential Start Valve ...
Page 100: ...Section 6 Operation MM147 D4 Hot Melt Unit 100 ...
Page 106: ...Section 7 Maintenance MM147 D4 Hot Melt Unit 106 ...
Page 110: ...Section 9 Specifications MM147 D4 Hot Melt Unit 110 Dimensions ...
Page 112: ...Section 10 Part Number List MM147 D4 Hot Melt Unit 112 D4 Unit ...
Page 113: ...MM147 D4 Hot Melt Unit Section 10 Part Number List 113 D4 Unit Continued ...
Page 120: ...Section 10 Part Number List MM147 D4 Hot Melt Unit 120 D4 Base Unit 776xx392 ...
Page 142: ...Section 11 Warranty MM147 D4 Hot Melt Unit 142 ...
Page 144: ...Section 12 Service MM147 D4 Hot Melt Unit 144 ...
Page 146: ...Appendix A Password Levels MM147 D4 Hot Melt Unit 146 Setting Level 0 as Default Continued ...
Page 148: ...Appendix B Power Requirements MM147 D4 Hot Melt Unit 148 ...
Page 150: ...Appendix C Instruction Sheets for Option Kits MM147 D4 Hot Melt Unit 150 ...
Page 208: ...5 Valco Melton IS0343 Anybus Installation Installation Continued ...
Page 245: ...Appendix E Communication Protocols Modus MM147 D4 Hot Melt Unit 162 ...