5
Valco Melton
IS0212
D and S Series Pump Change Procedure
Caution!
Caution!
Caution!
Caution!
Caution!
Install by cross-tightening the four (4) mb x 90 socket-
head cap screws. This will ensure the pump has a
uniform seal with the manifold, and will not leak.
Make sure the Spur Gear is under the sensor, otherwise
the unit will not function properly. If the spur gear is not
under the sensor, loosen the set screw and move the
spur gear to the correct position.
Valco Cincinnati Incorporated
411 Circle Freeway Drive
Cincinnati, Ohio 45246, USA
TEL: (1) 513-874-6550
FAX: (1) 513-874-3612
Melton S.L.U.
Pol. Industrial Agustinos
calle G, n. 34
31160 Orcoyen, Navarra, Spain
TEL: (34) 948-321-580
FAX: (34) 948-326-584
Valco Cincinnati, Ltd.
Unit 7-8
Hortonwood 32
Telford TF1 7YN England
TEL: (44) 1952-677911
FAX: (44) 1952-677945
Valco Cincinnati GmbH
Storkower Strasse 6
D-15749 Gallun, Germany
TEL: (49) 33764 8700
FAX: (49) 33764 87070
No part of this document may be reproduced without express permission from Valco Cincinnati, Inc. All rights reserved. Designs and other information may change without notice.
© 2013 Valco Cincinnati, Inc.
www.valcomelton.com
IS0212 4/13
To Replace an S
Series Unit Pump
1.
Remove the right-side and lower-front panels from the unit by
turning the latch and lifting up on the handle.
Warning!
Warning!
Warning!
Warning!
Warning!
Make sure the unit is at room temperature.
2.
Loosen, but do not remove, the set screw on the love joy coupling
closest to the pump.
3.
Loosen, but do not remove, one of the screws on each of the shaft
collars, and on both sides of the motor.
4.
Slide the shaft away from the pump until the coupling is no longer
on the shaft.
5.
Remove the four (4) m8 x 90 socket-head cap screws from the
pump.
6.
Remove the pump and O-rings.
7.
Install the new pump by reversing the above procedures.
Summary of Contents for D4
Page 1: ...D4 Hot Melt Unit Manual Number MM147 Revision Date 6 2018 ...
Page 4: ......
Page 10: ...Table of Contents MM147 D4 Hot Melt Unit 10 Module Status LED 170 Link Activity LED 170 ...
Page 20: ...Section 2 Safety and Use MM147 D4 Hot Melt Unit 20 ...
Page 22: ...Section 3 Basic Features MM147 D4 Hot Melt Unit 22 ...
Page 35: ...MM147 D4 Hot Melt Unit Section 5 Setup 35 Section 5 Setup Control Panel ...
Page 42: ...Section 5 Setup MM147 D4 Hot Melt Unit 42 Set Language Continued Next Page ...
Page 43: ...MM147 D4 Hot Melt Unit Section 5 Setup 43 Set Language Continued ...
Page 44: ...Section 5 Setup MM147 D4 Hot Melt Unit 44 Set Temperature Units ...
Page 47: ...MM147 D4 Hot Melt Unit Section 5 Setup 47 Hose Valve Temperature Continued ...
Page 54: ...Section 5 Setup MM147 D4 Hot Melt Unit 54 Beacon Alarm Setup Continued ...
Page 55: ...MM147 D4 Hot Melt Unit Section 5 Setup 55 Beacon 2 ...
Page 70: ...Section 5 Setup MM147 D4 Hot Melt Unit 70 Sequential Start Valve ...
Page 100: ...Section 6 Operation MM147 D4 Hot Melt Unit 100 ...
Page 106: ...Section 7 Maintenance MM147 D4 Hot Melt Unit 106 ...
Page 110: ...Section 9 Specifications MM147 D4 Hot Melt Unit 110 Dimensions ...
Page 112: ...Section 10 Part Number List MM147 D4 Hot Melt Unit 112 D4 Unit ...
Page 113: ...MM147 D4 Hot Melt Unit Section 10 Part Number List 113 D4 Unit Continued ...
Page 120: ...Section 10 Part Number List MM147 D4 Hot Melt Unit 120 D4 Base Unit 776xx392 ...
Page 142: ...Section 11 Warranty MM147 D4 Hot Melt Unit 142 ...
Page 144: ...Section 12 Service MM147 D4 Hot Melt Unit 144 ...
Page 146: ...Appendix A Password Levels MM147 D4 Hot Melt Unit 146 Setting Level 0 as Default Continued ...
Page 148: ...Appendix B Power Requirements MM147 D4 Hot Melt Unit 148 ...
Page 150: ...Appendix C Instruction Sheets for Option Kits MM147 D4 Hot Melt Unit 150 ...
Page 208: ...5 Valco Melton IS0343 Anybus Installation Installation Continued ...
Page 245: ...Appendix E Communication Protocols Modus MM147 D4 Hot Melt Unit 162 ...