MM147 - D4 Hot Melt Unit
Section 5 - Setup
73
User Inputs and Outputs - Continued
Outputs 1-4
Conditions to Turn Output ON
Disabled None
Setback On
Control is in Setback mode
Alarm
High Temperature Alarm OR,
Low Temperature Alarm OR,
RTD Disconnected Alarm OR,
Drive Fault (if equipped) OR,
Filter Alarm (if equipped) OR,
Communication Fault
System Ready & Pump On All zones have reached their respective temperature setpoints minus the
System
Ready Temperature Offset, the Ready Delay Time has elapsed AND
t
he pump is
ON.
System Ready
All zones have reached their respective temperature setpoints minus the
System
Ready Temperature Offset AND the Ready Delay Time has elapsed.
Power On
Control power is ON
Level 2
Material is below the Level 2 Sensor (if equipped)
Level 1
Material is below the Level 1 Sensor (if equipped) OR,
Hopper Feeder runs for more than 200 seconds without satisfying Level Sensor (if
equipped)
Fault/Stop The
tank
over-temperature thermostat is open OR,
Any zone temperature has increased above the Maximum Temperature Setting
OR,
The High Temperature Alarm or RTD Disconnected Alarm persists for more than
150 seconds
Note: Any of these conditions will cause the control to deactivate the master
control relay
Alarm/Level
High Temp Alarm OR,
Low Temp Alarm OR,
RTD Disconnected Alarm OR,
Drive Fault (if equipped) OR,
Filter Alarm (if equipped) OR,
Communication Fault OR,
Material is below the Low Level Sensor (if equipped) OR,
Hopper Feeder runs for more than 200 seconds without satisfying Level Sensor
(if equipped)
Ready & Level
All zones have reached their respective temperature setpoints minus the System
Ready Temperature Offset, the Ready Delay Time has elapsed AND the material is
below the level 1 sensor.
Pressure Alarm
The pump is ON, the pressure alarm delay has elapsed AND material pressure is
outside of the setpoint range.
Summary of Contents for D4
Page 1: ...D4 Hot Melt Unit Manual Number MM147 Revision Date 6 2018 ...
Page 4: ......
Page 10: ...Table of Contents MM147 D4 Hot Melt Unit 10 Module Status LED 170 Link Activity LED 170 ...
Page 20: ...Section 2 Safety and Use MM147 D4 Hot Melt Unit 20 ...
Page 22: ...Section 3 Basic Features MM147 D4 Hot Melt Unit 22 ...
Page 35: ...MM147 D4 Hot Melt Unit Section 5 Setup 35 Section 5 Setup Control Panel ...
Page 42: ...Section 5 Setup MM147 D4 Hot Melt Unit 42 Set Language Continued Next Page ...
Page 43: ...MM147 D4 Hot Melt Unit Section 5 Setup 43 Set Language Continued ...
Page 44: ...Section 5 Setup MM147 D4 Hot Melt Unit 44 Set Temperature Units ...
Page 47: ...MM147 D4 Hot Melt Unit Section 5 Setup 47 Hose Valve Temperature Continued ...
Page 54: ...Section 5 Setup MM147 D4 Hot Melt Unit 54 Beacon Alarm Setup Continued ...
Page 55: ...MM147 D4 Hot Melt Unit Section 5 Setup 55 Beacon 2 ...
Page 70: ...Section 5 Setup MM147 D4 Hot Melt Unit 70 Sequential Start Valve ...
Page 100: ...Section 6 Operation MM147 D4 Hot Melt Unit 100 ...
Page 106: ...Section 7 Maintenance MM147 D4 Hot Melt Unit 106 ...
Page 110: ...Section 9 Specifications MM147 D4 Hot Melt Unit 110 Dimensions ...
Page 112: ...Section 10 Part Number List MM147 D4 Hot Melt Unit 112 D4 Unit ...
Page 113: ...MM147 D4 Hot Melt Unit Section 10 Part Number List 113 D4 Unit Continued ...
Page 120: ...Section 10 Part Number List MM147 D4 Hot Melt Unit 120 D4 Base Unit 776xx392 ...
Page 142: ...Section 11 Warranty MM147 D4 Hot Melt Unit 142 ...
Page 144: ...Section 12 Service MM147 D4 Hot Melt Unit 144 ...
Page 146: ...Appendix A Password Levels MM147 D4 Hot Melt Unit 146 Setting Level 0 as Default Continued ...
Page 148: ...Appendix B Power Requirements MM147 D4 Hot Melt Unit 148 ...
Page 150: ...Appendix C Instruction Sheets for Option Kits MM147 D4 Hot Melt Unit 150 ...
Page 208: ...5 Valco Melton IS0343 Anybus Installation Installation Continued ...
Page 245: ...Appendix E Communication Protocols Modus MM147 D4 Hot Melt Unit 162 ...