MM147 - D4 Hot Melt Unit
Appendix B - Power Requirements
147
Appendix B - Power Requirements
System Power Requirement Calculation - D Series Units
WARNING!
Calculate all power requirements, as stated below, before hooking up power. OTHERWISE,
DEATH OR SEVERE INJURY AND DAMAGE TO EQUIPMENT AND/OR THE CIRCUIT
COULD OCCUR.
Power requirements for the D4 System (unit, hoses and guns) must be calculated before hooking up power, to verify
that the hoses and guns do not exceed the power rating for the D Series unit. Personnel injury, as well as serious
equipment damage, can result from overloading the system.
This calculation will depend on the following two factors:
•
The wattage for any hose/gun pair
•
The total wattage for all hoses and guns
Perform the system power requirement calculation for the D Series unit as follows, referring to Table 1, below:
Table 1. Maximum Allowable Wattage for the D Series Unit
Line
Description
Maximum
Wattage (W)
1
Total for hose/gun 1 pair
1800
2
Total for hose/gun 2 pair
1800
3
Total for hose/gun 3 pair
1400
4
Total for hose/gun 4 pair
1400
5
Total for all hoses and guns
8400
1. Add the power requirements of hose #1 and gun #1. Compare this value to the maximum wattage given
in Line 1 of Table 1.
2. Add the power requirements of hose #2 and gun #2. Compare this value to the maximum wattage given
in Line 2 of Table 1.
3. Add the power requirements of hose #3 and gun #3. Compare this value to the maximum wattage given
in Line 3 of Table 1.
4. Add the power requirements of hose #4 and gun #4. Compare this value to the maximum wattage given
in Line 4 of Table 1.
5. Add the power requirements of all hoses and all guns. Compare this value to the maximum wattage for all
hoses and guns given in Line 5 of Table 1.
6. If any of the power requirements calculated in steps 1-5 exceed any of the maximum allowable wattages
given in Table 1, the hose length or gun configuration must be changed, to reduce all power requirements
to below maximum-allowable wattages.
If each of the power requirements calculated in steps 1-5 is below the maximum allowable wattages given
in Table 1, the system power requirement is within allowable limits.
Summary of Contents for D4
Page 1: ...D4 Hot Melt Unit Manual Number MM147 Revision Date 6 2018 ...
Page 4: ......
Page 10: ...Table of Contents MM147 D4 Hot Melt Unit 10 Module Status LED 170 Link Activity LED 170 ...
Page 20: ...Section 2 Safety and Use MM147 D4 Hot Melt Unit 20 ...
Page 22: ...Section 3 Basic Features MM147 D4 Hot Melt Unit 22 ...
Page 35: ...MM147 D4 Hot Melt Unit Section 5 Setup 35 Section 5 Setup Control Panel ...
Page 42: ...Section 5 Setup MM147 D4 Hot Melt Unit 42 Set Language Continued Next Page ...
Page 43: ...MM147 D4 Hot Melt Unit Section 5 Setup 43 Set Language Continued ...
Page 44: ...Section 5 Setup MM147 D4 Hot Melt Unit 44 Set Temperature Units ...
Page 47: ...MM147 D4 Hot Melt Unit Section 5 Setup 47 Hose Valve Temperature Continued ...
Page 54: ...Section 5 Setup MM147 D4 Hot Melt Unit 54 Beacon Alarm Setup Continued ...
Page 55: ...MM147 D4 Hot Melt Unit Section 5 Setup 55 Beacon 2 ...
Page 70: ...Section 5 Setup MM147 D4 Hot Melt Unit 70 Sequential Start Valve ...
Page 100: ...Section 6 Operation MM147 D4 Hot Melt Unit 100 ...
Page 106: ...Section 7 Maintenance MM147 D4 Hot Melt Unit 106 ...
Page 110: ...Section 9 Specifications MM147 D4 Hot Melt Unit 110 Dimensions ...
Page 112: ...Section 10 Part Number List MM147 D4 Hot Melt Unit 112 D4 Unit ...
Page 113: ...MM147 D4 Hot Melt Unit Section 10 Part Number List 113 D4 Unit Continued ...
Page 120: ...Section 10 Part Number List MM147 D4 Hot Melt Unit 120 D4 Base Unit 776xx392 ...
Page 142: ...Section 11 Warranty MM147 D4 Hot Melt Unit 142 ...
Page 144: ...Section 12 Service MM147 D4 Hot Melt Unit 144 ...
Page 146: ...Appendix A Password Levels MM147 D4 Hot Melt Unit 146 Setting Level 0 as Default Continued ...
Page 148: ...Appendix B Power Requirements MM147 D4 Hot Melt Unit 148 ...
Page 150: ...Appendix C Instruction Sheets for Option Kits MM147 D4 Hot Melt Unit 150 ...
Page 208: ...5 Valco Melton IS0343 Anybus Installation Installation Continued ...
Page 245: ...Appendix E Communication Protocols Modus MM147 D4 Hot Melt Unit 162 ...