![VALCO MELTON D4 Manual Download Page 215](http://html1.mh-extra.com/html/valco-melton/d4/d4_manual_849618215.webp)
IS0344
Anybus Installation and Setup
ValcoMelton 7
Data Index Byte 2
The Data Index is equal to the Melter Parameters that may be accessed through the Ethernet/IP protocol. Only those
parameters listed can be accessed through remote mode. Parameters that require a system restart, including most
setup parameters, will still need to be accessed at the Melter.
The following is the Data Index list and valid parameters.
If the system is in Local Operation mode, all Data Types become
Read Only
and, in the case of
Write Only Indexes
, become
unavailable.
Data Index
Channel Data Type
Range
Description
4
-
RO
0 - 1
Remote Operation Mode (0=Local, 1=Remote)
7
-
WO
0 - 1
Clear Fault
11
-
RO
0 - 120 min
Ready Delay Time Remaining
23
-
RO
0x0000-0xFFFF
Current Alarm Type (See Table Below)
110
-
RW
0 – 1
Temperature Units (0=C, 1=F)
111
0-19
RW
0 – 1
Activate Temperature Zone
112
0-7
RW
0 – 1
Activate Hose/Gun Zone Pair
115
0-19
RW
40 – 230 C
Zone Temperature Set Point
120
0-19
RO
40 – 230 C
Zone Current Temperature
128
-
RW
5 – 190 C
Standby Temperature
135
-
RW
0 – 1440 min
AutoSetback Time
136
-
RW
0 – 1440 min
AutoStandby Time
142
-
RW
5 – 60 C
UnderTemp Fault Offset
152
-
RW
5 – 60 C
OverTemp Fault Offset
160
-
RW
1 – 180 min
Exit Standby Time
170
0-3
RW
0 – 2
Pump Auto Mode Input Speed Type
(0=0-10V, 1=0-2.8V, 2=Encoder)
171
0-3
RW
0 – 9999 m/min
Pump Minimum Speed - Encoder
172
0-3
RW
0 – 9999 RPM
Pump Creep Speed
173
0-3
RW
0 – 9999
Pump Ratio
174
0-3
RO
0 – 100%
Pump Manual Speed
175
0-3
RW
0 - 1
Pump Mode
176
0-3
RW
0 – 200
Pump Gain
177
0-3
RO
0 – 1
Pump Enable
178
0-3
RW
0 – 1
Grammage Enable
179
0-3
RW
10 – 3000 mm
Application Width (Grammage Only)
180
0-3
RW
1 – 200 g/m²
Application Weight (Grammage Only)
181
0-3
RW
0.8 – 100
Density (Grammage Only)
182
0-3
RO
0 – 9999 RPM
Pump Speed
183
0-3
RW
0 – 9999 mV
Pump Minimum Speed - Tach
200
-
RW
0 – 1
Seven-Day Clock Enabled
201
-
RO
0 – 1
Seven-Day Clock Status
202
-
RW
0 – 6
Clock – Day
203
-
RW
0 – 24
Clock – Hour
204
-
RW
0 - 60
Clock – Minute
Summary of Contents for D4
Page 1: ...D4 Hot Melt Unit Manual Number MM147 Revision Date 6 2018 ...
Page 4: ......
Page 10: ...Table of Contents MM147 D4 Hot Melt Unit 10 Module Status LED 170 Link Activity LED 170 ...
Page 20: ...Section 2 Safety and Use MM147 D4 Hot Melt Unit 20 ...
Page 22: ...Section 3 Basic Features MM147 D4 Hot Melt Unit 22 ...
Page 35: ...MM147 D4 Hot Melt Unit Section 5 Setup 35 Section 5 Setup Control Panel ...
Page 42: ...Section 5 Setup MM147 D4 Hot Melt Unit 42 Set Language Continued Next Page ...
Page 43: ...MM147 D4 Hot Melt Unit Section 5 Setup 43 Set Language Continued ...
Page 44: ...Section 5 Setup MM147 D4 Hot Melt Unit 44 Set Temperature Units ...
Page 47: ...MM147 D4 Hot Melt Unit Section 5 Setup 47 Hose Valve Temperature Continued ...
Page 54: ...Section 5 Setup MM147 D4 Hot Melt Unit 54 Beacon Alarm Setup Continued ...
Page 55: ...MM147 D4 Hot Melt Unit Section 5 Setup 55 Beacon 2 ...
Page 70: ...Section 5 Setup MM147 D4 Hot Melt Unit 70 Sequential Start Valve ...
Page 100: ...Section 6 Operation MM147 D4 Hot Melt Unit 100 ...
Page 106: ...Section 7 Maintenance MM147 D4 Hot Melt Unit 106 ...
Page 110: ...Section 9 Specifications MM147 D4 Hot Melt Unit 110 Dimensions ...
Page 112: ...Section 10 Part Number List MM147 D4 Hot Melt Unit 112 D4 Unit ...
Page 113: ...MM147 D4 Hot Melt Unit Section 10 Part Number List 113 D4 Unit Continued ...
Page 120: ...Section 10 Part Number List MM147 D4 Hot Melt Unit 120 D4 Base Unit 776xx392 ...
Page 142: ...Section 11 Warranty MM147 D4 Hot Melt Unit 142 ...
Page 144: ...Section 12 Service MM147 D4 Hot Melt Unit 144 ...
Page 146: ...Appendix A Password Levels MM147 D4 Hot Melt Unit 146 Setting Level 0 as Default Continued ...
Page 148: ...Appendix B Power Requirements MM147 D4 Hot Melt Unit 148 ...
Page 150: ...Appendix C Instruction Sheets for Option Kits MM147 D4 Hot Melt Unit 150 ...
Page 208: ...5 Valco Melton IS0343 Anybus Installation Installation Continued ...
Page 245: ...Appendix E Communication Protocols Modus MM147 D4 Hot Melt Unit 162 ...