2.Status
① The view of status
Status has written the hexadecimal number by 2 bytes of character string.
② Status allotment
00 Normal communication.
01 Communication fault.
3.Communication format Table 9
Measurement data lead
(Rate mete)
Command format @××RD1△△CR
Response format @××◇◇±0□□□□□△△CR
Measurement data read
(Ratio)
Command format
@××RD2△△CR
Response format @××◇◇±0□□□□□△△CR
OUT1 preset-value read
Command format
@××RP1△△CR
Response format @××◇◇±0□□□□□△△CR
OUT2 preset-value read
Command format
@××RP2△△CR
Response format @××◇◇±0□□□□□△△CR
OUT3 preset-value read
Command format
@××RP3△△CR
Response format @××◇◇±0□□□□□△△CR
OUT4 preset-value read
Command format
@××RP4△△CR
Response format @××◇◇±0□□□□□△△CR
OUT1 preset-value write
Command format
@××WP1±0□□□□□△△CR
Response format @××◇◇△△CR
OUT2 preset-value write
Command format
@××WP2±0□□□□□△△CR
Response format @××◇◇△△CR
OUT3 preset-value write
Command format
@××WP3±0□□□□□△△CR
Response format @××◇◇△△CR
OUT4 preset-value write
Command format
@××WP4±0□□□□□△△CR
Response format @××◇◇△△CR
××・・・・・ID number ◇◇・・・・・Status
△△・・・・・Checksum □□□□□・・Indicated value data
<Caution>
1.A decimal point does not go into transmission and received data.
2.Indicated value data is set to“-9999”or“99999 (Ratio 9999)”when a main part display
is“
― ― ― ― ―
blink”in a measurement data read
!
Summary of Contents for LV1000 Series
Page 16: ...12 The setting menu Each mode transition Preset value setting...
Page 17: ...13 Mode setting Scaling setting...
Page 18: ...14 Linearization setting 8 step preset value setting...
Page 19: ...15 Test mode...
Page 57: ...53 Analog adjustment mode flow chart...
Page 64: ...60 Dimensions Fig 26...