- 57 -
19.Communication function RS4(W) option
When use RS-485 communication, please set up baud rate, bit, parity, ID, and transceiver
switchingtime by mode No.C and d.
※RS4(W) option, D-sub9 pin(soldering type) and a hood are attached.
≪About a communication function≫
1.Signal level・・・IEE RS-485 conformity
2.Correspondence procedure・・・ R S 4:2-wire system Half-duplex system
RS4W:4-wire system Half-duplex system
3.Baud rate・・・(Mode setup is referred to "Mode №C" )
2400 bps
4800 bps
9600 bps(Factory setting)
19200 bps
4.Start bit
1-bit fixation
5.Stop bit
1-bit fixation
6.Data bit(Mode setup is referred to "Mode №C" )
7-bit・8-bit
7.Parity bit(Mode setup is referred to "Mode №C")
Nothing・Odd number・Even number
8.Communication code
ASCII code
9.Communication connector pin configuration(Meter side:D-sub9 pin)
※Since communication stops, in setting up at the time of each setup, please stop communication
or retry by timeout.
Fig.25
Meter side connector:XM3B-0922(OMRON make)