:When the 8 preset value is set, ch1 to ch8 are switched.
:When the title display of the linearization setting, the title display is changed.
(Ln.01A → Ln.01B → Ln.02A → ・・・ → Ln.21b → Ln.01A → ・・・)
:When the content of linearization set set is displayed,it changes to the title
display.
:When the analog adjustment mode set, analog adjustment No.(indicator A) is
switched. (Blank →A→b→C→d→Blank →A→b)
⑫ Up key
Measurement state:Present display is adjusted“0”when pushing with for 2sec ormore.
(When zero adjustment function is made effective, it is necessary to
setmode No.3.)
:When is pressing for 5 sec or more, while is pushing down ,
The measurement is restarted from the state of the power on.
(*1 Operation reset)
Setting state:Changes the value of the flashing digit during setup procedures.
Each time thekey is pressed, the number goes up by one.
:When analog output adjusted, the output bit value goes up.
⑬ Enter key
Power on state:When a power on while is pushing down ,“ ”display, and it
enters the state of the initialization selection.
Measurement state:The rate mete and the ratio are changed.
(It is necessary to set the Mode No.0)
:When is pressing for 5 sec or more, while is pushing down
The measurement is restarted from the state of the power on.
(*1 Operation reset)
Set list display:Shifts to the measurement.
Setting state:A set value is registered when each setting it, and it shifts to a set list.
:When the analog adjustment mode is set, the setting value is registered.
⑭ Reset key
Power on state:When a power on whili is pushing down ,analog adjustment mode functions.
Initialization state:When initialization is selected( display)is pushing down ,
It shifts to the measurement operation without initializing.
Measurement state:When pressing for 2 sec or more, resets the presetting output
Setting state:During setup procedures the display returns to the set list display,
without registering.
:When is pressing for 2sec or more, when analog adjusting it,
returns to the measurement.
*1 Operation reset
When + is pressing for 5 sec or more while displaying the measurement,
the measurement is started from the state at power on.
Please try for the unstable operation stc.Noise etc.
ENT
RST
ENT
RST
ENT
ENT
ENT
RST
RST
Summary of Contents for LV1000 Series
Page 16: ...12 The setting menu Each mode transition Preset value setting...
Page 17: ...13 Mode setting Scaling setting...
Page 18: ...14 Linearization setting 8 step preset value setting...
Page 19: ...15 Test mode...
Page 57: ...53 Analog adjustment mode flow chart...
Page 64: ...60 Dimensions Fig 26...