- 29 -
Mode No. Setting the least significant digit correction/domain“0”indication function
1
A B C D E
1.0 0
Domain“0”indication function
0:Function is invalid.
1:Function is effective.
Least significant digit correction
0:Real
1:Fixed at 0
2:0 or 5
[ Domain“0”indication function ]
Pleas use it, when indication “0”on the domain between any maximum value and the
minimum value.
0:Function is invalid.
Domain“0”indication function becomes invalid and dose not function.
1:Function is effective.
Domain“0”indication function becomes effective.
It functions by setup of domain 0 minimum / the maximum indicated value of a
scaling setup. (P.21 to 26 Reference)
[ Least significant digit correction ]
The form of indication for the least significant digit(digit on the right end)is
selected.
0:Real
Synchronized at the sampling time.
1:Fixed at 0
Always,“0”.
2:0 or 5
0-4 are expressed as 0, and 5-9 as 5.
Mode No. Setting the sampling time
2
A B C D E
2. 1.0
Sampling time
0.1-10.0 seconds(0.0 is 10.0 sec.)
[ Sampling time ]
Input signals are read by this time, and its average value is calculated and
indicated.
Use this setting for preventing flickering and for stabilizing indications.
<Caution>
It becomes effective after the samplint duration before it changes ends when
thesampling duration is changed.
!
Summary of Contents for LV1000 Series
Page 16: ...12 The setting menu Each mode transition Preset value setting...
Page 17: ...13 Mode setting Scaling setting...
Page 18: ...14 Linearization setting 8 step preset value setting...
Page 19: ...15 Test mode...
Page 57: ...53 Analog adjustment mode flow chart...
Page 64: ...60 Dimensions Fig 26...