- 24 -
2.5V
5V
Analog output value
-1000
0
2000
5000
Rate meter indicated value
【Analog output indication value:№⑨-⑩】
The indicated value when analogue and minimum outputting it and the indicated value at an
analog maximum output are set.
Setting range:-9999 to 9999 <A decimal point is interlocked with the mode No.0>
<Caution>
When setting as <analog output minimum indication value = analog maximum output
indication value>, the analog output becomes minimum value.
[Example of setting analog output]
The analog input AV4 (0 to 5V) range. It outputs it synchronizing with the indication.
At indication value (-1000), the output is minimum (OV).
At indication value (5000), the output is maximum (5V).
1 2 3 4 A B C D E
Analog output minimum indicated value. ○ ○ ○ ● - 1 0 0 0 (-1000)
1 2 3 4 A B C D E
Analog output maximum indicated value. ○ ○ ○ ◎ 0 5 0 0 0 (5000)
A B C D E
Mode No.A A.0 1 (Rate meter indication)
(It synchronizes with sampling time)
●・・・Light up ○・・・Light disappears
◎・・・Light blinks
The analog output is shown in the figure below. Fig.18
<Caution>
1.When the analog output method is set to “Synchronize with the display sampling duration”,
it outputs it by internal sampling duration.
Please set up “synchronization to an indicated value”to output proportion to an
indicated value.
2.Although it is proportional to the set-up slope, if it becomes the minimum exaggerated
value “
-9999
blink”or the maximum exaggerated value “
9999
blinks”, it will become
0% or 102.4% of output compulsorily.
〔Indicated value setup of the output minimum < Indicated value setup of the output maximum〕
“
-9999
blink”・・・・・・・0% output
“
9999
blink”・・・・・102.4% output
〔Indicated value setup of the output minimum > Indicated value setup of the output maximum〕
“
-9999
blink”・・・・・102.4% output
!
!
Summary of Contents for LV1000 Series
Page 16: ...12 The setting menu Each mode transition Preset value setting...
Page 17: ...13 Mode setting Scaling setting...
Page 18: ...14 Linearization setting 8 step preset value setting...
Page 19: ...15 Test mode...
Page 57: ...53 Analog adjustment mode flow chart...
Page 64: ...60 Dimensions Fig 26...