【Optional specification】
<Preset output +2 step output :option P4>
Preset
output
+
2 step
output
Output terminal
Output terminals no.4-5 (OUT3),17-18 (OUT4)
Comparative system
Upper limit, lower limit (immediately) and lower limit
(delay). (selectable)
Output mode
Comparison, maintenance,(selectable)
Output selection
Function stop, Rate mete, Raito,(selectable)
※ Only OUT4 can select the disconnection detection.
Preset value setting
The presetting program mode setting is also selectable.
Output judgment
Judgment output is compared with the indication value by
preset value.
Output circuit
Tow-row relay 1a output
[ Control capacity / Maximum permissible power ]
AC125V 0.6A (Resistance load)
AC250V 0.3A (Resistance load)
DC 30V 2A (Resistance load)/60W MAX
[ The maximum control current ]
2A MAX
※ Can be used within control current 2A and control
capacity / permissible power.
Output indication
During presetting output, the OUT3 and OUT4 LED are
activated
Hysteresis setting
0-3999 (4 digits to disregard decimal point)
Output reset
The key to the pushed for 2 sec or more.
Hysteresis operation
Invalid or selects it from effective.
※ When the output mode is only“Compareson”,it operates.
Preset output state
distinction time
It outputs it continuing set time (0.0-99.9 sec) after it
enters the output area at the output area.
<Preset output +8 step output :option P10>
Preset
output
+
8 step
output
Output terminal
D-sub 9 pin connector Output from 2-9(Pin1 is GND)
Comparative system
Upper limit, lower limit (immediately) and lower limit
(delay). (selectable)
Output mode
Comparison, maintenance,(selectable)
Output selection
Function stop, Rate mete, Raito,(selectable)
Preset value setting
The 8 step presetting program mode setting is also
selectable.
Output judgment
Judgment output is compared with the indication value by
preset value.
Output circuit
8 step NPN open collector output
Maximum: DC30V 50mA max
Output reset
The key to the pushed for 2 sec or more.
< Preset output + 10 step output specification:option P12 >
Becames a composition of Preset output + 2 step output + 8 step output
Please refer to the specification of option P4, P10.
/75VA MAX
RST
RST
Summary of Contents for LV1000 Series
Page 16: ...12 The setting menu Each mode transition Preset value setting...
Page 17: ...13 Mode setting Scaling setting...
Page 18: ...14 Linearization setting 8 step preset value setting...
Page 19: ...15 Test mode...
Page 57: ...53 Analog adjustment mode flow chart...
Page 64: ...60 Dimensions Fig 26...