2
What is TR PMIU series?
Thank you for purchasing TR PMIU series. TR PMIU series is graphical color touch panel unit that ladder logic
function is built into. All models have serial communication port, and some models has Expansion slot for IO unit.
Moreover, they have data logger and alarm function. The display, the operation, and the control of a small-scale
machine can be handled with this one. This will replace many switches, timers, and relays used of your
machine/system.
Requirement
Following things are necessary for developing TR series.
Personal computer (PC)
TR
PGMS01
programming
software
requires
IBM
PC/AT
Compatible
system
that
has
Pentium
Ⓡ
800MHz or equivalent CPU, 256MB of RAM, 800MB of HDD free space, Windows OS (Windows
Ⓡ
2000
SP4, Windows
Ⓡ
XP Professional SP2 or Home edition SP2) , Display (800x600 High-color 16bit),
Keyboard and mouse, one USB or RS232C Serial port (We recommend USB port).
TR PGMS01 software
You must install this software before start development. All settings of the TR series are done from this.
DC 24V Power supply
Power source of all TR series. The power of most digital Expansion I/O unit is supplied from PMIU unit,
but the Expansion I/O units that has relay output or analog I/O requires specially power supply for relay
coil/AD converter. Protect the power supply with the circuit breaker for safety.
USB cable (type A male/type B male) or Serial cable
USB connection is recommended. Serial communication (RS233C) is more low-speed than USB, and the
function is limited. If you want to connect by serial communication, refer
Append. C.
Device necessary for debugging or check of operation
Expansion I/O unit, Tools, wiring material, device connected with TR unit, etc. Developing as much as
possible in a near environment facilitates developing, and decreases the trouble. The device actually
used is recommended to be prepared as much as possible.
About TR PGMS01
TR PGMS01 is setting and programming software for the all TR series. This can use all TR series including TR
PMIU series touch panel monitor and Expansion I/O unit for it.
Installation and uninstallation of TR PGMS is similar to general Windows software. To start setup, click
“setup.exe” in program folder, then set up wizard is started. When the installation is completed, reboot your PC.
To remove TR PGMS from your computer, open the control panel of Windows, and select "Add or remove
programs", "Change or remove programs".
We recommend this software to be used in an English environment. Some functions (function related to display
and language) might not be able to be used normally under 2bytes character (language chiefly used in east Asia,
Middle East, etc) environment.
Summary of Contents for TR PMIU
Page 11: ...1 Chapter Chapter Chapter Chapter 1 1 1 1 Introduction Introduction Introduction Introduction ...
Page 15: ...5 Chapter 2 Chapter 2 Chapter 2 Chapter 2 Hardware Hardware Hardware Hardware ...
Page 23: ...13 Input Wiring for TR PDIO0808 P Output ...
Page 24: ...14 Wiring for TR PDIO0808 N Input Output ...
Page 26: ...16 Input Input Wiring for TR PDIX1600 ...
Page 28: ...18 Output Wiring for TRSDOX0016N ...
Page 39: ...29 Chapter Chapter Chapter Chapter 3 3 3 3 TR PGMS TR PGMS TR PGMS TR PGMS ...
Page 83: ...73 Chapter 5 Chapter 5 Chapter 5 Chapter 5 Tag Tag Tag Tag ...
Page 98: ...88 Chapter Chapter Chapter Chapter 6 6 6 6 Task Task Task Task ...
Page 124: ...114 Chapter 8 Chapter 8 Chapter 8 Chapter 8 Screen Screen Screen Screen ...
Page 167: ...157 Note for the numbers of alarm message ...
Page 176: ...166 Appendix Appendix Appendix Appendix ...
Page 181: ...171 ...
Page 182: ...172 ...