Procedure 2
Diagnostic Test Program Execution Check
Insert the Diagnostics Disk in the USB FDD, turn on the computer and run the test. Refer to
Chapter 3,
Tests and Diagnostics,
for more information about the diagnostics test procedures.
Floppy disk drive test error codes and their status names are listed in Table 2-6. Make sure
the floppy disk is formatted correctly and that the write protect tab is disabled. If any other
errors occur while executing the FDD diagnostics test, go to Check 1.
Table 2-6 FDD error code and status
Code Status
01h
Bad command error
02h
Address mark not found
03h Write
protected
04h
Record not found
06h Media
removed
08h
DMA overrun error
09h
DMA boundary error
10h CRC
error
20h FDC
error
40h Seek
error
60h
Not drive error
80h
Time out error
EEh
Write buffer error
Check 1 If the following message appears, disable the write protect tab on the floppy disk.
If any other message appears, perform Check 2.
Write protected
Check 2 Make sure the floppy disk is formatted correctly. If it is, go to Procedure 3.
Summary of Contents for Tecra M9
Page 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Page 12: ...1 Hardware Overview 1 ii CONFIDENTIAL TECRA M9 Maintenance Manual 960 631 ...
Page 45: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Page 46: ...2 Troubleshooting Procedures 2 ii CONFIDENTIAL TECRA M9 Maintenance Manual 960 631 ...
Page 121: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Page 122: ...3 Tests and Diagnostics 3 ii CONFIDENTIAL TECRA M9 Maintenance Manual 960 631 3 ...
Page 126: ...3 Tests and Diagnostics 3 vi CONFIDENTIAL TECRA M9 Maintenance Manual 960 631 ...
Page 228: ...3 Tests and Diagnostics 3 31 SETUP 3 102 CONFIDENTIAL TECRA M9 Maintenance Manual 960 631 ...
Page 229: ... CONFIDENTIAL Chapter 4 Replacement Procedures ...
Page 230: ...4 Replacement Procedures 4 ii CONFIDENTIAL TECRA M9 Maintenance Manual 960 631 4 ...
Page 347: ... CONFIDENTIAL Appendices ...
Page 348: ...Appendices App ii CONFIDENTIAL TECRA M9 Maintenance Manual 960 631 ...
Page 354: ...Appendices App viii CONFIDENTIAL TECRA M9 Maintenance Manual 960 631 ...
Page 394: ...Appendices Appendix C Pin Assignments 24 CONFIDENTIAL TECRA M9 Maintenance Manual 960 631 ...
Page 404: ...Appendices Appendix E Key Layout E 2 CONFIDENTIAL TECRA M9 Maintenance Manual 960 631 ...
Page 408: ...Appendices Appendix F Wiring diagrams F 4 CONFIDENTIAL TECRA M9 Maintenance Manual 960 631 ...
Page 414: ...Appendices Appendix I Reliability I 2 CONFIDENTIAL TECRA M9 Maintenance Manual 960 631 ...