e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 230
1775
General
Card reader format infor-
mation -3
ALL
-
SYS
Security key
“KKKKKKKKKKKK” (12
digits) <hexadecimal
number> in the [Key
Information] of the [Sec-
tor Number] set in the
code 08-1773 should
be entered.
5
1776
General
Card authentication LDAP
server
ALL
0
<0-100>
SYS
LDAP server number
for the card authentica-
tion when a noncontact
IC card is used should
be set.
1
1777
General
Card authentication LDAP
search index
ALL
-
SYS
LDAP search index
when a noncontact IC
card is used is set.
11
1778
General
Hang-up period of control
panel at the 3rd misentry of
administrator's password
ALL
1
<0-7>
SYS
0: No hang-up
1: 0.5 minutes (= 30
seconds)
2: 1 minute
3: 3 minutes
4: 5 minutes
5: 10 minutes
6: 15 minutes
7: 30 minutes
1
1779
Network
Default data saving direc-
tory of "Scan to File"
ALL
0
<0-2>
SYS
0: Local directory
1: REMOTE 1
2: REMOTE 2
1
1781-0
Network
Notification of
scan job
When job
completed
ALL
0
<0-1>
SYS
Sets the notification
method of scan job
completion.
0: Invalid
1: Valid
4
1781-1
On error
ALL
0
<0-1>
SYS
4
1782
Network
File name format of "Save
as file" and Email transmis-
sion
ALL
0
<0-6>
SYS
Sets the naming
method of the file of
"Save as file" and Email
transmission.
0: [FileName]-[Data]-
[Page]
1: [FileName]-[Page]-
[Data]
2: [Data]-[FileName]-
[Page]
3: [Data]-[Page]-[File-
Name]
4: [Page]-[FileName]-
[Data]
5: [Page]-[Data]-[File-
Name]
6: [HostName]_[Data]-
[Page]
1
Setting mode (08) <e-STUDIO202L/203L/232/233/282/283>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
07/11