e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
PREVENTIVE MAINTENANCE (PM)
4 - 22
* e1.
Separation roller (SFB)
Apply an even coat of grease (Alvania No.2) to all round the inside of the spring.
When replacing the separation roller, apply adequate amount of white grease (Molykote
HP-300) on the places of the holder shown in the figure (4 places).
Note:
Note:
Make sure that the grease does not adhere to the roller surface. Wipe it off with alcohol if
adhered.
* f1.
Main charger case / Needle electrode
Clean the main charger case with a cloth soaked in water and squeezed tightly, and then
wipe them with a dry cloth.
Clean the needle electrode only with the main charger cleaner.
Replace the needle electrode with a new one if it is damaged regardless of the number of
output pages which have been mode.
Note:
Note:
Do not touch the needle electrode with your bare hand when attaching the needle electrode.
* g1.
Transfer / separation charger case and transfer / separation wire
Clean the transfer / separation charger case with a cloth soaked in water and squeezed
tightly, and then wipe them with a dry cloth.
Replace the wire with a new one if it is damaged regardless of the number of output pages
which have been mode.
Notes:
• Do not deform the metal plate of the transfer guide roller.
• Be careful of the following when attaching a new wire (length: 353 mm)
- Insert the wire securely into the V-grooves of the front and rear sides.
- Do not twist the wire.
- Do not touch the wire with your bare hand.
Fig. 4-16
Fig. 4-17
Apply grease on the inner surface
Apply white grease