e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 198
799
General
Forcible end of trial period
PRT/
SCN
-
SYS
[CANCEL]: Cancel
[EXECUTION]: Forc-
ible end
When the “Forcible end
of trial period” is per-
formed, “0” is set in the
code (08-673) to end up
the trial period forcibly.
3
800-0
Fuser
Temperature
control lower
limit
(OHP film)
Center
thermistor
ALL
8
<0-12>
M
0: 130°C
1: 135°C
2: 140°C
3: 145°C
4: 150°C
5: 155°C
6: 160°C
7: 165°C
8: 170°C
9: 175°C
10: 180°C
11: 185°C
12: 120°C
4
800-1
Side
thermistor
ALL
6
<0-12>
M
4
801-0
Fuser
Temperature
control lower
limit
(Thick paper
1)
Center
thermistor
ALL
8
<0-12>
M
0: 130°C
1: 135°C
2: 140°C
3: 145°C
4: 150°C
5: 155°C
6: 160°C
7: 165°C
8: 170°C
9: 175°C
10: 180°C
11: 185°C
12: 120°C
4
801-1
Side
thermistor
ALL
6
<0-12>
M
4
802-0
Fuser
Temperature
control lower
limit
(Thick paper
2)
Center
thermistor
ALL
8
<0-12>
M
0: 130°C
1: 135°C
2: 140°C
3: 145°C
4: 150°C
5: 155°C
6: 160°C
7: 165°C
8: 170°C
9: 175°C
10: 180°C
11: 185°C
12: 120°C
4
802-1
Side
thermistor
ALL
9
<0-12>
M
4
803-0
Fuser
Temperature
control lower
limit
(Thick paper
3)
Center
thermistor
ALL
8
<0-12>
M
0: 130°C
1: 135°C
2: 140°C
3: 145°C
4: 150°C
5: 155°C
6: 160°C
7: 165°C
8: 170°C
9: 175°C
10: 180°C
11: 185°C
12: 120°C
4
803-1
Side
thermistor
ALL
10
<0-12>
M
4
804-0
Fuser
Temperature
control lower
limit
(Envelope)
Center
thermistor
ALL
8
<0-12>
M
0: 130°C
1: 135°C
2: 140°C
3: 145°C
4: 150°C
5: 155°C
6: 160°C
7: 165°C
8: 170°C
9: 175°C
10: 180°C
11: 185°C
12: 120°C
4
804-1
Side
thermistor
ALL
10
<0-12>
M
4
Setting mode (08) <e-STUDIO202L/203L/232/233/282/283>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure