© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
ADJUSTMENT
3 - 11
3
Fig. 3-8 Grid pattern
<Procedure>
Perform 08-477 and check the value.
When the value is 0.
[0] [5] [Power ON]
[1] ([3](05-445, 498) for duplexing)
[FAX]
A:
05-401 (Lower drawer, A3/LD)
200±0.5 mm (0.125 mm/step)
B:
05-411 (Lower drawer, A3/LD)
52±0.5 mm (0.05 mm/step)
Key in the same value for 05-410.
C:
05-421 (Lower drawer, A3/LD)
200±0.5 mm (0.125 mm/step)
D: 05-441 (Lower drawer, A3/LD), 440 (Upper drawer, A4/LT), 444 (PFP, A4/LT),
443 (LCF, A4/LT), 442 (Bypass feed, A4/LT), 445 (Duplexing, A3/LD)
52±0.5 mm(0.4 mm/step)
E:
05-498-0 (Lower drawer, A3/LD),
498-1 (Upper drawer, A4/LT)
52±0.5 mm (0.05 mm/step)
A
21
6
1
B, E
D
6
30
2
C
10
Feeding direction
04/09