e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 14
[B] Reproduction ratio adjustment of the primary scanning direction
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON
(Adjustment Mode)
(2) Place a ruler on the original glass (along the direction from the rear to the front of the equipment).
(3) Press [FAX] to make a copy at the mode of A3 (LD), 100% and standard drawer of the equipment
(Refer to *).
* Perform 08-477 and check the value.
If the value is 0, use the lower drawer.
If the value is 1, use the upper drawer.
(4) Measure the distance A from 10 mm to 270 mm of the copied image of the ruler.
(5) Check if the distance A is within the range of 260±0.5 mm.
(6) If not, use the following procedure to change values and repeat the steps (3) to (5) above.
(Adjustment Mode)
(Key in the code [405])
[START]
(Key in a value (acceptable values: 0 to 255))
Press the [ENTER] or the [INTERRUPT] button (stored in memory).
(“100% A” is displayed.)
* The larger the adjustment value is, the higher the reproduction ratio and the longer the dis-
tance A become (approx. 0.125 mm/step).
Fig. 3-12
50
100
150
200
250
A
Feeding direction
Copied image of the ruler
04/09