e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 86
Notes:
• The digit after the hyphen in “Code” of the following table is a sub code.
• e-STUDIO200L/230/230L/280:In “RAM”, the NVRAM of the board in which the data of each
code is stored is indicated. “M” stands for the LGC board, “SYS” and “UTY” stands for the
SYS board and “NIC” stands for the NIC board.
Setting mode (08) <e-STUDIO200L/230/230L/280>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
200
General
Date and time setting
ALL
-
<13 dig-
its>
-
Year/month/date/day/
hour/minute/second
Example:
03 07 0 13 13 27 48
“Day” - “0” is for
“Sunday”. Pro-
ceeds Monday
through Saturday
from “1” to “6”.
5
201
General
Destination selection
ALL
EUR: 0
UC: 1
JPN: 2
<0-2>
M
0: EUR
1: UC
2: JPN
1
202
User
interface
Counter installed externally
ALL
0
<0-3>
M
0: No external counter
1: Coin controller
2: Copy key card
(This value is valid
only when “2” is set
to 08-201.)
3: Key copy counter
1
203
General
Line adjustment mode
ALL
0
<0-1>
M
0: For factory ship-
ment
1: For line
*
Field: “0” must be
selected
1
204
User
interface
Auto-clear timer setting
ALL
3
<0-10>
SYS
Timer to return the
equipment to the
default settings when
the [START] button is
not pressed after the
function and the mode
are set
0: Not cleared
1 to 10:Set number x 15
sec.
1
205
User
interface
Auto power save mode
timer setting
ALL
EUR: 11
UC: 11
JPN: 6
Others:
11
<0, 6-15>
SYS
Timer to automatically
switch to the Auto
power save mode when
the equipment has not
been used
0: Invalid
6: 3min.
7: 4min.
8: 5min.
9: 7min.
10: 10min.
11: 15min.
12: 20min.
13: 30min.
14: 45min.
15: 60min.
1
10/06