© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 175
2
404-0
Fuser
Temperature
drop setting in
ready status
(Center ther-
mistor)
The first
drop
ALL
1
<0-10>
M
This code is valid only
when “20” is set to 08-
886.
Setting value x -5°C:
from 0°C to -50°C
4
404-1
The sec-
ond drop
ALL
1
<0-10>
M
4
404-2
The third
drop
ALL
1
<0-10>
M
4
404-3
The fourth
drop
ALL
1
<0-10>
M
4
405-0
Fuser
Temperature
drop setting in
ready status
(Side ther-
mistor)
The first
drop
ALL
4
<0-10>
M
4
405-1
The sec-
ond drop
ALL
4
<0-10>
M
4
405-2
The third
drop
ALL
4
<0-10>
M
4
405-3
The fourth
drop
ALL
4
<0-10>
M
4
407
Fuser
Fuser roller temperature in
ready status
(Side thermistor)
ALL
8
<0-12>
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
1
409
Fuser
Fuser roller temperature at
energy saver mode
(Center thermistor)
ALL
0
<0-13>
M
0: OFF
1: 40°C
2: 50°C
3: 60°C
4: 70°C
5: 80°C
6: 90°C
7: 100°C
8: 110°C 9: 120°C
10: 130°C
11: 140°C
12: 150°C
13: 160°C
1
410
Fuser
Fuser roller temperature
during printing
(Center thermistor/Plain
paper)
ALL
8
<0-14>
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
1
411
Fuser
Fuser roller temperature on
standby
(Center thermistor)
ALL
8
<0-12>
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
1
Setting mode (08) <e-STUDIO202L/203L/232/233/282/283>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
07/11