e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
TROUBLESHOOTING
5 - 34
[E860]
RADF jam access cover open
Is the RADF jam access cover opened?
YES
Remove the original, if any, and close the RADF jam access cover.
NO
Is the RADF jam access cover switch working? (Perform the input check: 03-[FAX]ON/[7]/
[C])
l
l
l
l
l
l
l
l
l
NO
1) Check if the connector of the RADF jam access cover switch is dis-
connected.
2) Check if the connector CN8 on the RADF board is disconnected.
3) Check if the connector pins are disconnected or the harnesses are
open circuited.
4) Check if the conductor pattern on the RADF board is short circuited
or open circuited.
5) Replace the RADF jam access cover switch.
6) Replace the RADF board.
YES
Replace the RADF board.
[E870]
RADF open jam
Is the RADF opened?
YES
Remove the original, if any, and close the RADF.
NO
Is the RADF opening/closing sensor adjusted within the specified range?
NO
Adjust the RADF opening/closing sensor.
YES
Is the RADF opening/closing sensor working?
(Perform the input check: 03-[FAX]ON/[7]/[D])
l
l
l
l
l
l
l
l
l
NO
1) Check if the connector of the RADF opening/closing sensor is dis-
connected.
2) Check if the connector CN6 on the RADF board is disconnected.
3) Check if the connector pins are disconnected or the harnesses are
open circuited.
4) Check if the conductor pattern on the RADF board is short circuited
or open circuited.
5) Replace the RADF opening/closing sensor.
6) Replace the RADF board.
YES
Replace the RADF board.