e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
TROUBLESHOOTING
5 - 106
11)Skew (inclined image)
Fig. 5-11
Defective area
Step
Check items
Prescription
Drawers
LCF
1
Is the drawer or LCF properly
installed?
Install the drawer or LCF properly.
2
Is there too much paper in the drawer
or LCF?
Reduce paper to 550 sheets or less.
(2500 sheets or less/stack for LCF)
3
Is the corner of the paper folded?
Change the direction of the paper
and set it again.
4
Are the side guides of the drawer or
LCF properly installed?
Adjust the position of the side guides.
Feed roller
5
Is the surface of the feed roller dirty?
Clean the feed roller surface with
alcohol, or replace the roller.
Rollers
6
Are the roller and shaft secured?
Check and tighten the E-rings, pins,
clips and setscrews.
Registration roller
7
Is the spring detached from the regis-
tration roller?
Attach the spring correctly. Clean the
roller if it is dirty.
Pre-registration guide
8
Is the pre-registration guide properly
installed?
Correct it.
Carriage-1
9
Is the carriage-1 slanted?
Adjust the carriage-1.
Feeding direction