TROUBLESHOOTING
5 - 80
[F200] Data overwrite kit (GP-1050) is taken off
(e-STUDIO202L/230/230L/280)
Clear the service call “F200”. (Key in “0” at 08-633.)
* When the Data overwrite kit (GP-1050) is removed from the equipment, the service call “F200”
occurs.
[F200] Data overwrite kit (GP-1060) is taken off (e-STUDIO202L/203L/232/233/282/283)
Check the system ROM version (08-900) since the countermeasure to be taken varies.
T377SY0*329 or later
(* represents a letter of the alphabet corresponding to the destination.)
Download the system firmware again.
P. 6-1 "6. FIRMWARE UPDATING"
Earlier than T377SY0*329
(* represents a letter of the alphabet corresponding to the destination.)
Clear the service call “F200”. (Key in “0” at 08-633.)
* When the Data overwrite kit (GP-1060) is removed from the equipment, the service call “F200”
occurs.