e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 86
(5) Remove the processing tray.
(6) Loosen the screw on the home position sen-
sor plate at the front.
Fig. 3-112
(7) Adjust the position of the front jogging plate
home position sensor (S6) with reference to
the index.
• EX. 1
If the width is 319 mm in step (4), the dif-
ference from the standard is +2 mm, it
requires relocation of the sensor in the
direction of arrow A by 2 mm.
• EX. 2
If the width is 316 mm in step (4), the dif-
ference from the standard is -1 mm; it
requires relocation of the sensor in the
direction of arrow B by 1 mm.
Fig. 3-113
Home position
sensor plate
Screw
A
B
Sensor