e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
TROUBLESHOOTING
5 - 100
5) Blurred image
Fig. 5-5
Defective area
Step
Check items
Prescription
Paper
1
Is the paper in the drawer or LCF
damp?
Change paper. Avoid storing paper in
damp place.
Bedewed scanner
2
Is the scanner bedewed?
Clean the scanner.
Drum
3
Is the drum surface wet or dirty?
Wipe the drum with a piece of dry
cloth.
*
Do not use alcohol or other
organic solvents.
Ozone exhaust
4
Is the exhaust fan operating prop-
erly?
Check the connection of connector.
Replace the ozone exhaust fan.
5
Is the ozone filter stained or dam-
aged?
Replace the ozone filter.