Adjusting the overlap of the sensor flag
If the overlap between the sensor and the flag is wrong for some reason, perform the following adjust-
ment.
<Procedure>
(1) Remove the processing tray unit.
(2) Loosen the mounting screw of the front/rear
jogging plate adjusting plate; then, move the
adjusting plate to the left and the right.
Fig. 3-116
(3) Tighten the screw so that the overlap
between the flag of the front/rear jogging
rack plate and the sensor is 1.5 mm to 2.0
mm.
Fig. 3-117
Jogging plate
adjusting plate
Jogging plate
adjusting plate
Screw
Screw
Adjusting
plate
Adjusting
plate
Sensor
Sensor flag
1.5 mm to 2.0 mm