© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
ADJUSTMENT
3 - 37
3
[B] Connection for developer bias adjustment
Fig. 3-23
[C] Connection for main charger adjustment
Fig. 3-24
Front cover opening/closing switch
Ground to the
machine frame
(green cable)
(-) terminal:
Connect with the white cable
(+) terminal:
Connect with the black cable
Front cover opening/closing switch
Ground to the
machine frame
(green cable)
(-) terminal:
Connect with the white cable
(+) terminal:
Connect with the
red cable (thick line)