FIRMWARE UPDATING
6 - 56
<Updating Finisher ROM>
(1) Install the ROM to the download jig.
Make sure the direction is correct (P.6-33 "Fig. 6-35").
(2) Turn OFF the power of the equipment.
(3) Take off the finisher rear cover.
Fig. 6-60
* Connect the finisher interface cable with the equipment after removing the finisher rear cover.
(4) Connect the download jig with the jig connector on the finisher control PC board.
Fig. 6-61
(5) Change the setting of he DIP switch on the finisher control PC board.
Change all the setting of the DIP switch (1-8) to OFF.
Finisher rear cover
Connector