e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 196
747
Mainte-
nance
(Remote)
Automatic ordering func-
tion of supplies
Supplier's address
ALL
-
SYS
Maximum 100 letters
11
748
Mainte-
nance
(Remote)
Automatic ordering func-
tion of supplies
Notes
ALL
-
SYS
Maximum 128 letters
11
758
Mainte-
nance
(Remote)
Information about supplies
Part number of toner car-
tridge
ALL
-
SYS
Maximum 20 digits
11
759
Mainte-
nance
(Remote)
Information about supplies
Order quantity of toner car-
tridge
ALL
1
<1-99>
SYS
1
760
Mainte-
nance
(Remote)
Information about supplies
Condition number of toner
cartridge
ALL
1
<1-99>
SYS
1
765
Mainte-
nance
(Remote)
Automatic ordering sup-
plies
Display
ALL
EUR: 2
UC: 0
JPN: 2
<0-2>
SYS
0: Valid (FAX/Internet
FAX)
1: Valid (FAX/Internet
FAX/HTTP)
2: Invalid
1
767
Mainte-
nance
(Remote)
Service Notification setting
ALL
0
<0-2>
SYS
Enables to set up to 3
E-mail addresses to be
sent.(08-768, 777, 778)
0: Invalid
1: Valid (E-mail)
2: Valid (FAX)
1
768
Mainte-
nance
(Remote)
Destination E-mail address
ALL
-
SYS
Maximum 192 letters
11
769
Mainte-
nance
(Remote)
Total counter information
transmission setting
ALL
0
<0-1>
SYS
0: Invalid
1: Valid
1
770
Mainte-
nance
(Remote)
Total counter transmission
date setting
ALL
0
<0-31>
SYS
0 to 31
1
771
Mainte-
nance
(Remote)
PM counter notification set-
ting
ALL
0
<0-1>
SYS
0: Invalid
1: Valid
1
772
Mainte-
nance
Dealer's name
ALL
-
SYS
Maximum 100 letters
Needed at initial regis-
tration
11
773
Mainte-
nance
Login name
ALL
-
SYS
Maximum 20 letters
Needed at initial regis-
tration
11
774
Mainte-
nance
(Remote)
Display setting of [Service
Notification] button
ALL
EUR: 0
UC: 1
JPN: 0
<0-1>
SYS
0: Not displayed
1: displayed
1
775
Mainte-
nance
(Remote)
Sending error contents of
equipment
ALL
0
<0-1>
SYS
0: Invalid
1: Valid
1
776
Mainte-
nance
(Remote)
Setting total counter trans-
mission interval
(Hour/Hour/Minute/Minute)
ALL
-
SYS
1
777
Mainte-
nance
(Remote)
Destination E-mail address
2
ALL
-
SYS
Maximum 192 letters
11
Setting mode (08) <e-STUDIO202L/203L/232/233/282/283>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
07/11