e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 212
1372
Counter
Heater and energizing time
accumulating counter Dis-
play/0 clearing
ALL
0
<8 digits>
M
Counts up the heater
control time accumu-
lated (when power of
the equipment is ON)
but does not count at
the Sleep Mode. When
the counter value of the
fuser roller is cleared,
this counter value is
also cleared in sync at
the PM support mode.
1
1376
Counter
Toner cartridge drive
counter
ALL
0
<8 digits>
M
Counts the rotation
number of the toner
cartridge.
1
1378
Counter
Counter for period of time
fuser unit is at ready tem-
perature
ALL
0
<8 digits>
M
Counts up the heater
control time accumu-
lated (when the equip-
ment is at ready status).
When the counter value
of the fuser roller is
reset, this counter is
also reset in sync at the
PM support mode.
1
1380
Counter
Counter for period of time
fuser unit is at printing tem-
perature
ALL
0
<8 digits>
M
Counts up the heater
control time accumu-
lated (during printing).
When the counter value
of the fuser roller is
reset, this counter is
also reset in sync at the
PM support mode.
1
1382
Counter
Counter for period of time
fuser unit is at energy sav-
ing temperature/Counter
reset
ALL
0
<8 digits>
M
Counts up the heater
control time accumu-
lated (when the equip-
ment is in the Energy
Saving Mode).
When the counter value
of the fuser roller is
reset, this counter is
also reset in sync at the
PM support mode.
1
1385
Image
process-
ing
Number of output pages
(Thick paper 1)
ALL
0
<8 digits>
M
Counts up when the
registration sensor is
ON. When the counter
value of the fuser roller
is cleared, this counter
value is also cleared in
sync at the PM support
mode.
1
1386
Image
process-
ing
Number of output pages
(Thick paper 2)
ALL
0
<8 digits>
M
Counts up when the
registration sensor is
ON. When the counter
value of the fuser roller
is cleared, this counter
value is also cleared in
sync at PM support
mode.
1
Setting mode (08) <e-STUDIO202L/203L/232/233/282/283>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
07/11