Reel Engage Switch
g202429
Figure 87
1.
Switch mount bracket
3.
Reel lever tab
2.
Reel engage switch
4.
Engagement lever
The reel engage switch is a normally open proximity switch. The switch is
attached to the handle assembly switch mount bracket (
).
When the cutting unit is not engaged, the tab on the cutting unit engagement
lever is positioned away from the target end of the reel engage switch so that
the switch remains open. The tab on the engagement lever is moved next to the
switch when the cutting unit is engaged causing the switch to close.
Greensmaster
®
eFlex 1800, 2100 and 2120
Page 5–37
Electrical System: Adjustments
12189SL Rev E