Testing the Sensor (continued)
4. If the EZ turn sensor LED did not function correctly:
A. Ensure that the EZ turn sensor is properly adjusted (refer to the
Operator’s
Manual
). If necessary, adjust the sensor and return to step
above.
B. Ensure that the key switch is O
FF
and then disconnect the EZ turn sensor
connector from the machine wire harness.
C. Turn the key switch to the S
TART
position to wake up the machine and
then turn the key switch to the R
UN
position.
g202574
Figure 109
1.
Terminal A
2.
Terminal C
3.
Terminal B
D. Connect the multimeter common (-) test probe to the harness connector
terminal C (black wire) and second test probe to the harness connector
terminal A (pink wire) (
). Check with the multimeter that the
harness connector has 12 VDC circuit voltage present.
E. If the sensor connector has circuit voltage present and sensor LED
did not function, replace the EZ turn sensor. Adjust the sensor after
installation (refer to the
Operator’s Manual
).
5. After you complete the EZ turn sensor testing, plug the sensor connector into
the machine wire harness.
6. Connect the battery pack; refer to
Connecting the Lithium Battery Pack
(page 5–7)
.
Greensmaster
®
eFlex 1800, 2100 and 2120
Page 5–59
Electrical System: Testing the Electrical Components
12189SL Rev E