Traction Circuit is Inoperative (continued)
Possible Causes
Correction
The parking brake latch switch is not adjusted
correctly or is damaged.
Use the InfoCenter Diagnostics screen to
check the parking brake latch switch operation.
Adjust or replace the parking brake latch switch
if necessary.
The wire harness connections or wires are
loose or damaged.
Check the electrical connections. Repair the
wire harness as necessary.
A problem exists with the traction or reel drive
system.
Refer to
Chapter 4: Traction and Reel Drive
.
The electric motor is damaged.
Note:
Fault should be displayed on the
InfoCenter if the electric motor is damaged.
Use the InfoCenter Faults and Diagnostics
screens to check the reel circuit operation.
Check the electric motor and circuit wires.
Repair as necessary.
Cutting Unit Circuit is Inoperative
Possible Causes
Correction
The reel engage switch is not adjusted or is
damaged.
Use the InfoCenter Diagnostics screen to
check the reel engage switch operation. Adjust
or replace the reel engage switch if necessary.
The wire harness connections or wires are
loose or damaged.
Check the electrical connections. Repair the
wiring as necessary.
The electric motor is damaged.
Note:
Fault should be displayed on the
InfoCenter if the electric motor is damaged.
Check the electric motor and circuit wires.
Repair as necessary.
Machine is Inoperative and InfoCenter Power Light Indicates That a Fault Has
Occurred
Possible Causes
Correction
System fault has been detected by controller.
Use the Faults screen information in the
InfoCenter section of this chapter to help
identify source of problem.
An electrical fault occurred that can be reset
by the controller.
Attempt to restart the machine to see if the
machine operation has returned to normal. If
the fault still remains, use the Faults screen
information in the InfoCenter section of this
chapter to help identify source of problem.
Note:
The EZ turn switch has to be O
N
, the mow circuit has to be engaged, and
the cutting unit needs to be raised before the EZ turn system will operate.
EZ Turn System is Not Working
Possible Causes
Correction
The EZ turn circuit wire harness connections
or wires are loose or damaged.
Check the electrical connections. Repair the
wiring as necessary.
The EZ turn switch on the control panel is
damaged.
Use the InfoCenter Diagnostics screen to
check the EZ turn switch operation. Replace
the EZ turn switch if necessary.
Troubleshooting:
Page 3–4
Greensmaster
®
eFlex 1800, 2100 and 2120
12189SL Rev E