Idler Assembly (Forward Rotating Groomer Drive)
g228304
Figure 206
1.
Pivot hub
6.
Right drive plate
11.
Bearing (2 each)
2.
Spacer
7.
O-ring
12.
Retaining ring
3.
Spring
8.
Retaining ring
13.
Locknut
4.
Idler bracket
9.
Grease fitting
5.
Spacer
10.
Idler pulley
The groomer right drive plate assembly incorporates the idler system for
tensioning the groomer drive belt. The idler system uses a spring to maintain
proper belt tension.
Removing the Idler Assembly (Forward Rotating Groomer Drive)
1. Park machine on level surface. Turn key switch to the O
FF
position and
remove key from the switch. Ensure that the traction lever is in the N
EUTRAL
position. Engage parking brake.
2. Disconnect the battery pack; refer to
Connecting the Lithium Battery Pack
(page 8–3)
.
3. If idler pulley (item 10 in
) needs to be serviced, remove locknut
and slide pulley with bearings from idler bracket. Remove retaining ring
and bearings from idler pulley.
4. If idler bracket (item 4 in
) or pivot hub are to be removed from
drive plate:
A. Remove right drive plate assembly from right side of cutting unit; refer to
Grooming Reel (Forward Rotating Groomer Drive) (page 8–10)
.
Belt Driven Groomer: Service and Repairs
Page 8–24
Greensmaster
®
eFlex 1800, 2100 and 2120