Diagnostics Screen (continued)
•
Throttle
identifies the throttle control setting (in volts) that is used by the TEC
to determine the electric motor speed. Rotating the speed wheel should
change the setting. Voltage for throttle settings should range from 0.35 to
4.80 VDC depending on the speed wheel location.
•
Target RPM
lists the desired electric motor RPM based on the speed control
setting. Rotating the speed wheel should change the setting.
•
Motor RPM
identifies the actual electric motor RPM. The motor RPM should
be very close to the Target RPM.
•
12V Supply
indicates the supplied voltage available for the 12 VDC circuits
(InfoCenter, EZ turn sensor). The 12V Supply should typically be slightly
higher than 12.0 VDC.
•
5V Supply
indicates the supplied voltage available for the 5 VDC circuit
(speed control). The 5V Supply should typically be slightly higher than 5.0
VDC.
•
CAN bus
identifies whether the machine communication bus status is normal
or not.
To return to the main menu screen from the diagnostics screen, press the
menu/back button (as indicated by the
at the bottom of the screen).
Electrical System: InfoCenter Display
Page 5–30
Greensmaster
®
eFlex 1800, 2100 and 2120
12189SL Rev E