172-65710M-04 (SC-F71 Parameters/Functions) 23 Dec 2021
110
Input 1_Input range low [Engineering Mode: Function block No. 21 (
Fn21
)]
Parameter symbol
Data range
Factory set value
1.P GS L
Input 1_Minimum value of input range to (Input 1_ Input range
high
1 digit)
[Varies with the setting of the Decimal point position.]
Refer to the Input range table for the input range of each input
type.
Product identification code
specified at the time of order.
For unspecified V/I inputs: 0.0
Refer to “4. Parameters that are Initialized/Modified when Setting is Changed”
for the parameters that are automatically converted when the Input 1_Input
range low is changed.
When 3 to 7 (pressure control operation [MC-(V)COS(R)]) is set to Input
1_Control action, the set value for the parameter should be entered with
the same pressure unit selected for Input 1_Valve coefficient F.
Input 2_Input range low [Engineering Mode: Function block No. 22 (
Fn22
)]
Parameter symbol
Data range
Factory set value
2.P GS L
TC/RTD inputs and Voltage (V)/Current (I) inputs
(For other than Remote setting input):
Input 2_Minimum value of input range to (Input 2_Input
range high
1 digit)
[Varies with the setting of the Decimal point position.]
Voltage (V)/Current (I) inputs (For Remote setting input):
Input 1_Minimum value of input range to (Input 2_Input
range high
1 digit)
[Varies with the setting of the Decimal point position.]
Refer to the Input range table for the input range of each input
type.
Same as Input 1_Input
range low
Not displayed when No function is selected in in Function block No. 58: Select
function for Input 2 (Engineering mode).
Refer to “4. Parameters that are
Initialized/Modified when Setting is Changed” for the parameters that are
automatically converted when the Input 2_Input range low is changed.
When 3 to 7 (pressure control operation [MC-(V)COS(R)]) is set to Input
2_Control action, the set value for the parameter should be entered with
the same pressure unit selected for Input 2_Valve coefficient F.
Input range table
The input resolution may vary with the selected input range, unit, and decimal
point position.
TC input
Input type
Decimal point position
C
F
K
No decimal place
-200 to +400
C
-328 to +752
F
-200 to +1372
C
-328 to +2502
F
One decimal place
-200.0 to +400.0
C
-328.0 to +752.0
F
-200.0 to +1372.0
C
-328.0 to +2502.0
F
J
No decimal place
-200 to +400
C
-328 to +752
F
-200 to +1200
C
-328 to +2192
F
One decimal place
-200.0 to +400.0
C
-328.0 to +752.0
F
-200.0 to +1200.0
C
-328.0 to +2192.0
F
T
No decimal place
-200 to +400
C
-328 to +752
F
One decimal place
-200.0 to +400.0
C
-328.0 to +752.0
F
S
No decimal place
-50 to +1768
C
-58 to +3214
F
One decimal place
-50.0 to +1768.0
C
-58.0 to +3214.0
F
R
No decimal place
-50 to +1768
C
-58 to +3214
F
NOTE
NOTE
Summary of Contents for SC-F71
Page 17: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 16 ...
Page 18: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 17 Differential temperature control ...
Page 114: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 113 Setting procedure ...
Page 131: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 130 Setting procedure ...
Page 134: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 133 Setting procedure ...
Page 141: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 140 Setting procedure ...
Page 153: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 152 Setting procedure ...
Page 158: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 157 Setting procedure ...
Page 168: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 167 Setting procedure ...
Page 172: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 171 Setting procedure ...
Page 175: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 174 Setting procedure ...
Page 180: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 179 Setting procedure ...
Page 185: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 184 ...
Page 199: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 198 Setting procedure ...
Page 207: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 206 Setting procedure ...
Page 249: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 248 Setting procedure ...
Page 280: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 279 Setting procedure ...
Page 293: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 292 Checking PID values ...
Page 303: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 302 Setting procedure ...
Page 316: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 315 Setting procedure ...
Page 320: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 319 Setting procedure ...
Page 347: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 346 Operating procedure ...
Page 388: ...172 65710M 04 SC F71 Parameters Functions 23 Dec 2021 387 Setting procedure ...