Main Menu
90
3. Press the
F4 ENTER K
EY
to start the Function Test. Display shows test currently being performed.
The Function test ends automatically. Press any key on the controller to return the unit to normal
operation.
Any alarm codes recorded during the test can be viewed through the controller’s Alarm List menu at the
end of the test.
Manual Function Test
The Manual Function Test menu allows technicians to perform specific diagnostic tests on individual
components or turn several components on at the same time to perform a system test.
NOTE: THE UNIT STOPS when the Manual Function Test menu is entered. A technician can then
select the control circuit or component to be checked/tested from the items shown in the menu.
Complete the following steps to enter the Manual Function Test menu.
With the Unit turned On, Allow Unit to start and stabilize and the Display to show the unit status display
(setpoint):
1. Press the
PTI K
EY
to open the PTI Menu.
2. Press the
F2 OR F3 UP/DOWN K
EY
to scroll to “Manual Function Test”.
3. Press the
F4 ENTER K
EY
to enter the Manual Function Test Menu.
To test a unit component:
1. Press the
F2
OR
F3 U
P
/D
OWN
key to scroll to desired component test:
•
[PHASE DIRECTION]
•
[HEATER]
•
[COMPRESSOR]
•
[EVAPORATOR FAN HIGH]
•
[EVAPORATOR FAN LOW]
•
[CONDENSER FAN]
•
[ECONOMIZER VALVE]
•
[DIGITAL VALVE]
2. Press the
F4
ENTER
KEY
to start the component test. Display will change the component state from off
to on.
3. Verify component performance: Display will show expected current and actual current on phase 1, 2
and 3.
4. Press the
F4
ENTER
KEY
again to stop test. Display will change component state from on to off.
System Test (test multiple components at the same time):
1. Press the
F2
OR
F3 U
P
/D
OWN
key to scroll to the first component.
2. Press the
F4
ENTER
KEY
to turn the component on.
3. Press the
F3
key to scroll to select next component. Press the
F4
ENTER
KEY
to turn component on.
Summary of Contents for 098203
Page 2: ......
Page 3: ...MAGNUM TK 60275 4 MM Rev 3 08 15 Copyright 2012 Ingersoll Rand EMEIA Printed in Ireland...
Page 193: ...Refrigeration Maintenance 191 Figure 163 Filter Drier...
Page 200: ...Refrigeration Maintenance 198 Figure 169 Receiver Tank Figure 170 Water Cooled Condenser Tank...
Page 257: ...255 Schematic Diagram RELEASED 19 Sep 2013...
Page 258: ...256 Wiring Diagram Page 1 of 2 RELEASED 19 Sep 2013...
Page 259: ...257 Wiring Diagram Page 2 of 2 RELEASED 19 Sep 2013...
Page 263: ......