Main Menu
75
Fresh Air Vent Man - AFAM Mode
Can be set to OFF or AFAM.
OFF - Will override all settings and keep the AFAM door completely closed.
AFAM – Will allow and air exchange Rate and or Delay to be set.
See “Starting the AFAM System” on page 114 for more information about setting up AFAM.
Figure 53: AFAM Mode
Fresh Air Vent Man - AFAM+ Mode
Can be set to OFF, AFAM, or AFAM+.
OFF - Will override all settings and keep the AFAM door completely closed.
AFAM – Will allow and air exchange Rate and or Delay to be set.
AFAM+ – Will allow a CO2 Max to be set. Some container prefix allow O2 MIN to be set.
See “Advanced Fresh Air Management Plus (AFAM+) System” on page 117 for more information about
setting up AFAM+.
Figure 54: AFAM+ Mode