![Thermo King 098203 Maintenance Manual Download Page 120](http://html1.mh-extra.com/html/thermo-king/098203/098203_maintenance-manual_1104405120.webp)
Main Menu
118
4. Press the
F2
or
F3
key to select
AFAM+
and Press and hold
F4
to accept the selection.
Figure 97: Controlled Atmosphere (CA) Menu
5. Press the
F1
key several times to return to the standard display.
6. Press the
M
ENU
F4
key to enter the main menu. Press the
F2
or
F3
key to scroll to
Setpoint/Control
Menu and Press
F4
to expand the menu.
7. Press the
F2
or
F3
key to scroll to [Fresh Air Vent Man] line.
8. Press the
F4
key to enter the Fresh Air Vent Man menu.
9. Press the
F2
or
F3
key to scroll between [OFF], [AFAM], and [AFAM+].
•
[OFF]: Vent door closes and/or remains closed. AFAM Delay and CO2 Max settings disappear.
•
[AFAM]: Controller uses enter AFAM DELAY and AFAM RATE time to adjust FAE door to user
setting.
•
[AFAM]: Controller uses enter AFAM DELAY and CO2 Max to adjust FAE door to user setting.
Figure 98: Fresh Air Vent Man Menu
WARNING: The vent door and motor actuator arm move immediately when the
F4
key is
pressed to enable the AFAM+ system. Keep hands and tools away from the air exchange system
components to prevent personal injury or unit damage.
Summary of Contents for 098203
Page 2: ......
Page 3: ...MAGNUM TK 60275 4 MM Rev 3 08 15 Copyright 2012 Ingersoll Rand EMEIA Printed in Ireland...
Page 193: ...Refrigeration Maintenance 191 Figure 163 Filter Drier...
Page 200: ...Refrigeration Maintenance 198 Figure 169 Receiver Tank Figure 170 Water Cooled Condenser Tank...
Page 257: ...255 Schematic Diagram RELEASED 19 Sep 2013...
Page 258: ...256 Wiring Diagram Page 1 of 2 RELEASED 19 Sep 2013...
Page 259: ...257 Wiring Diagram Page 2 of 2 RELEASED 19 Sep 2013...
Page 263: ......